ClimaGuard® Residential Glass

ClimaGuard Titan

Efficient, neutral glass that is easy to process

Perfectly suited for both residential construction projects and commercial applications, Guardian ClimaGuard® Titan is easily processed. This Low-e glass combines energy efficiency, a neutral appearance and a higher resistance to external factors than other ClimaGuard glass.

Thermal insulation

Minimises heating costs during winter months

Single product

Heat-treatment or annealed applications

Transparency

71% visible light transmission reduces the need for artificial light

Easy to process

No edge deletion required

Specs and Downloads

Glass Substrates

  • ExtraClear

Applications

  • Facades
  • Windows
  • Doors

Manufacturing Options

  • Tempered
  • Laminated
  • Heat Soaked
  • Annealed

Available Sizes

  • Maximum Height x Width: 3210 x 6000 mm

Recommended coating positions

  • Double glazed: 3

Edge Deletion

  • Required: No

Application type

  • Can be used in: Insulating Glass Unit

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for color and performance

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for color and performance

* Please see Colour Disclaimer at the bottom of the page for additional information.

Performance Data

  • Visible Light

    1. Transmittance [%] 71
    2. Reflectance outside [%] 11
    3. Reflectance inside [%] 12
  • Solar Energy

    1. Solar Factor (g) [%] 67.13
    2. Direct transmission[%] 51
    3. Reflectance outside [%] 23
    4. Absorption [%] 25
    5. UV [%] 47
  • Thermal Properties

    1. U-Value ∆T=15°K [W/m²·K] 1.39
  • Composition

    1. Composition 4 mm / 16 mm / 4 mm CG Titan - Coating on surface #3
    2. Glass 1 & Coating Guardian ExtraClear
    3. Glass 2 & Coating ClimaGuard Titan on Guardian ExtraClear
    4. Gap 1 10% Air, 90% Argon
    5. Calculation Standard GOST EN 410-2014

Displayed colors are intended to represent actual color. Color is a function of light and reflectivity and cannot be accurately portrayed online. Actual glass samples should be used to determine color. Please order a sample and discuss color with your Guardian Architectural Design Manager to ensure you are pleased with your SunGuard selection before ordering glass for your project.

The thermal stress guideline is only a rough guide to the thermal safety of a glazing. Other factors such as large glass areas, shapes and patterns, thick glass, glass damaged during shipping, handling or installation, orientation of the building, exterior shading, overhangs/fins that reduce wind speed, and areas with high daily temperature fluctuations can all increase the probability of thermal breakage. The results shown are not for any specific glazing installation and do not constitute a warranty against glass breakage.