SunGuard® SuperNeutral®

SN 30 T

Light without the heat

Architects and building owners want high performance coated glass products that deliver abundant natural light combined with energy savings and solar protection. The Guardian SunGuard® SuperNeutral® (SN) range meets these requirements. These multi-functional coatings offer high selectivity solar protection on a neutral-looking glass (including neutral blue) for a wide range of applications such as fully glazed facades, roof glazing and large framed windows.

Excellent selectivity

Combining high solar protection with high light transmission

Available on laminated glass

For acoustics, security and comfort

Uniform colour

Sophisticated neutral reflected and transmitted colour, with available matching spandrel

Specs and Downloads

Thickness

  • 3 - 12 mm

Applications

  • Facades
  • Windows
  • Doors
  • Curtain Walls
  • Roofs
  • Skylights

Manufacturing Options

  • Tempered
  • Laminated
  • Heat Soaked
  • Heat Strengthened

Available Sizes

  • Maximum Height x Width: 3210 x 6000 mm

Recommended coating positions

  • Double glazed: 2

Edge Deletion

  • Required: Yes

Application type

  • Can be used in: Insulating Glass Unit

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for color and performance.

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for color and performance.

* Please see Colour Disclaimer at the bottom of the page for additional information.

Performance Data

  • TRANSMITTANCE

    1. Visible Light 30
    2. Ultraviolet 12
    3. Solar Energy 13
    4. Light to Solar Gain (LSG) 1.63
  • Reflectance

    1. Visible Light Outside 16
    2. Visible Light Inside 19
    3. Solar Energy Outside 30
  • U-VALUE

    1. Summer Daytime - Air (Btu/hr·ft²·F) 0.28
  • Heat Gain

    1. Relative Heat Gain (RHG) 46
    2. Solar Heat Gain Coefficient (SHGC) 0.19
  • Composition

    1. Composition 6 mm / 12 mm / 6 mm - coating on surface #2
    2. Glass 1 & Coating SunGuard SN 30 T on Clear
    3. Glass 2 & Coating Clear
    4. Gap 1 100% Air
    5. Calculation Standard NFRC 2010

Displayed colors are intended to represent actual color. Color is a function of light and reflectivity and cannot be accurately portrayed online. Actual glass samples should be used to determine color. Please order a sample and discuss color with your Guardian Architectural Design Manager to ensure you are pleased with your SunGuard selection before ordering glass for your project.

The thermal stress guideline is only a rough guide to the thermal safety of a glazing. Other factors such as large glass areas, shapes and patterns, thick glass, glass damaged during shipping, handling or installation, orientation of the building, exterior shading, overhangs/fins that reduce wind speed, and areas with high daily temperature fluctuations can all increase the probability of thermal breakage. The results shown are not for any specific glazing installation and do not constitute a warranty against glass breakage.