SunGuard® eXtra Selective

SNX 60

Photo Credit: Filip Slapal

Boost thermal insulation, banish energy costs

By delivering world-class selectivity, eXtra Selective (SNX) 60 helps reduce energy costs by lowering the demand for artificial lighting, air conditioning and heating. With a transparent appearance, low reflection and consistent colour, it is the ideal choice for completely glazed facades. It delivers optimum thermal insulation when used in a standard double-glazed unit.

Excellent selectivity

Combining high solar protection with high light transmission

Uniform appearance and performance

Neutral, transparent colour and low reflection

Can be laminated

For safety, security or acoustic applications

Unique patented foil

Protects glass during processing

Product Information

Glass Substrates

  • ExtraClear

Thickness

  • 4 - 12 mm

Applications

  • Facades
  • Windows
  • Doors
  • Curtain Walls
  • Roofs

Manufacturing Options

  • Laminated
  • Bent
  • Heat Strengthened
  • Annealed
  • HT version with TPF foil for Heat-Treatable applications: Tempered

Available Sizes

  • Maximum Height x Width: 3210 x 6000 mm

Recommended coating positions

  • Double glazed: 2
  • Triple Glazed: 2

Edge Deletion

  • Required: Yes

Application type

  • Can be used in: Insulating Glass Unit

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for colour and performance.

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for colour and performance.

* Please see Colour Disclaimer at the bottom of the page for additional information.

Performance Data

  • Visible Light

    1. Transmittance [%] 59.6
    2. Reflectance outside [%] 12.9
    3. Reflectance inside [%] 12.9
    4. Colour Rendering Index (Ra) 93.0
  • Solar Energy

    1. Solar Factor (g) [%] 29.4
    2. Direct transmission[%] 27.4
    3. Reflectance outside [%] 38.0
    4. Absorption [%] 34.5
    5. UV [%] 7.8
  • Coefficients

    1. Shading Coefficient (sc) [g/0.87] 0.34
  • Thermal Properties

    1. U-Value [W/m²·K] 1.0
  • Composition

    1. Composition 6mm / 16 mm / 4 mm - Coating on surface #2
    2. Glass 1 & Coating SunGuard SNX 60 on Guardian ExtraClear
    3. Glass 2 & Coating Guardian ExtraClear
    4. Gap 1 10% Air, 90% Argon
    5. Calculation Standard EN 410:2011 / EN 673:2011
  • Visible Light

    1. Transmittance [%] 53.9
    2. Reflectance outside [%] 14.6
    3. Reflectance inside [%] 16.3
    4. Colour Rendering Index (Ra) 92.0
  • Solar Energy

    1. Solar Factor (g) [%] 27.1
    2. Direct transmission[%] 24.2
    3. Reflectance outside [%] 38.9
    4. Absorption [%] 36.9
    5. UV [%] 5.2
  • Coefficients

    1. Shading Coefficient (sc) [g/0.87] 0.31
  • Thermal Properties

    1. U-Value [W/m²·K] 0.5
  • Composition

    1. Composition 6mm / 16 mm / 4 mm / 16 mm / 4 mm - Coating on surface #2 and #5
    2. Glass 1 & Coating SunGuard SNX 60 on Guardian ExtraClear
    3. Glass 2 & Coating Guardian ExtraClear
    4. Glass 3 & Coating ClimaGuard Premium2 on Guardian ExtraClear
    5. Gap 1 10% Air, 90% Argon
    6. Gap 2 10% Air, 90% Argon
    7. Calculation Standard EN 410:2011 / EN 673:2011
  • Visible Light

    1. Transmittance [%] 59.9
    2. Reflectance outside [%] 12.8
    3. Reflectance inside [%] 12.8
    4. Colour Rendering Index (Ra) 95.0
  • Solar Energy

    1. Solar Factor (g) [%] 29.5
    2. Direct transmission[%] 28.0
    3. Reflectance outside [%] 44.0
    4. Absorption [%] 28.0
    5. UV [%] 8.6
  • Coefficients

    1. Shading Coefficient (sc) [g/0.87] 0.34
  • Thermal Properties

    1. U-Value [W/m²·K] 1.0
  • Composition

    1. Composition 6mm / 16 mm / 4 mm - Coating on surface #2
    2. Glass 1 & Coating SunGuard SNX 60 on Guardian UltraClear
    3. Glass 2 & Coating Guardian ExtraClear
    4. Gap 1 10% Air, 90% Argon
    5. Calculation Standard EN 410:2011 / EN 673:2011
  • Visible Light

    1. Transmittance [%] 54.4
    2. Reflectance outside [%] 14.5
    3. Reflectance inside [%] 16.1
    4. Colour Rendering Index (Ra) 94.0
  • Solar Energy

    1. Solar Factor (g) [%] 27.4
    2. Direct transmission[%] 24.9
    3. Reflectance outside [%] 44.8
    4. Absorption [%] 30.2
    5. UV [%] 5.7
  • Coefficients

    1. Shading Coefficient (sc) [g/0.87] 0.31
  • Thermal Properties

    1. U-Value [W/m²·K] 0.5
  • Composition

    1. Composition 6mm / 16 mm / 4 mm / 16 mm / 4 mm - Coating on surface #2 and #5
    2. Glass 1 & Coating SunGuard SNX 60 on Guardian UltraClear
    3. Glass 2 & Coating Guardian ExtraClear
    4. Glass 3 & Coating ClimaGuard Premium2 on Guardian UltraClear
    5. Gap 1 10% Air, 90% Argon
    6. Gap 2 10% Air, 90% Argon
    7. Calculation Standard EN 410:2011 / EN 673:2011

Displayed colors are intended to represent actual color. Color is a function of light and reflectivity and cannot be accurately portrayed online. Actual glass samples should be used to determine color. Please order a sample and discuss color with your Guardian Architectural Design Manager to ensure you are pleased with your SunGuard selection before ordering glass for your project.

The thermal stress guideline is only a rough guide to the thermal safety of a glazing. Other factors such as large glass areas, shapes and patterns, thick glass, glass damaged during shipping, handling or installation, orientation of the building, exterior shading, overhangs/fins that reduce wind speed, and areas with high daily temperature fluctuations can all increase the probability of thermal breakage. The results shown are not for any specific glazing installation and do not constitute a warranty against glass breakage.