SunGuard®SuperNeutral

SN 70/37

Great performance has never been so clear

Architects and owners regularly choose coated glass products that offer very high natural light transmission while ensuring energy savings and solar protection. SunGuard® SN 70/37 meets these requirements. This multifunctional coating minimises the need for artificial light and offers excellent solar protection combined with outstanding thermal insulation.

Excellent selectivity

Combining high solar protection with high light transmission

Uniform colour

Sophisticated neutral reflected and transmitted colour, with available matching spandrel

Dream big

Ideal for fully glazed façade and roof glazing

Can be laminated

Available on laminated and acoustic laminated glass for more security and comfort

Paragon Tower, Istanbul, Turkey

Product Information

Glass Substrates

  • ExtraClear

Thickness

  • 4 - 12 mm

Applications

  • Facades
  • Windows
  • Doors
  • Curtain Walls
  • Roofs
  • Skylights

Manufacturing Options

  • Laminated
  • Bent
  • Heat Strengthened
  • Annealed
  • HT version with TPF foil for Heat-Treatable applications: Tempered

Available Sizes

  • Maximum Height x Width: 3210 x 6000 mm

Recommended coating positions

  • Double glazed: 2
  • Triple Glazed: 2

Edge Deletion

  • Required: Yes

Application type

  • Can be used in: Insulating Glass Unit

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for colour and performance.

Visual Appearance

Use the glass visualizer to get an introductory understanding of how glass will appear in use. Use the Glass Analytics tools to explore even more options for colour and performance.

Performance Data

  • Visible Light

    1. Transmittance [%] 70.1
    2. Reflectance outside [%] 11.2
    3. Reflectance inside [%] 12.2
    4. Colour Rendering Index (Ra) 93.0
  • Solar Energy

    1. Solar Factor (g) [%] 36.8
    2. Direct transmission[%] 34.9
    3. Reflectance outside [%] 38.7
    4. Absorption [%] 26.4
    5. UV [%] 10.9
  • Coefficients

    1. Shading Coefficient (sc) [g/0.87] 0.42
  • Thermal Properties

    1. U-Value [W/m²·K] 1.0
  • Composition

    1. Composition 6mm / 16 mm / 4 mm - Coating on surface #2
    2. Glass 1 & Coating SunGuard SN 70/37 on Guardian ExtraClear
    3. Glass 2 & Coating Guardian ExtraClear
    4. Gap 1 10% Air, 90% Argon
    5. Calculation Standard EN 410:2011 / EN 673:2011
  • Visible Light

    1. Transmittance [%] 63.4
    2. Reflectance outside [%] 13.6
    3. Reflectance inside [%] 15.7
    4. Colour Rendering Index (Ra) 92.0
  • Solar Energy

    1. Solar Factor (g) [%] 33.9
    2. Direct transmission[%] 30.5
    3. Reflectance outside [%] 40.0
    4. Absorption [%] 29.6
    5. UV [%] 7.3
  • Coefficients

    1. Shading Coefficient (sc) [g/0.87] 0.39
  • Thermal Properties

    1. U-Value [W/m²·K] 0.5
  • Composition

    1. Composition 6mm / 16 mm / 4 mm / 16 mm / 4 mm - Coating on surface #2 and #5
    2. Glass 1 & Coating SunGuard SN 70/37 on Guardian ExtraClear
    3. Glass 2 & Coating Guardian ExtraClear
    4. Glass 3 & Coating ClimaGuard Premium2 on Guardian ExtraClear
    5. Gap 1 10% Air, 90% Argon
    6. Gap 2 10% Air, 90% Argon
    7. Calculation Standard EN 410:2011 / EN 673:2011

Displayed colors are intended to represent actual color. Color is a function of light and reflectivity and cannot be accurately portrayed online. Actual glass samples should be used to determine color. Please order a sample and discuss color with your Guardian Architectural Design Manager to ensure you are pleased with your SunGuard selection before ordering glass for your project.

The thermal stress guideline is only a rough guide to the thermal safety of a glazing. Other factors such as large glass areas, shapes and patterns, thick glass, glass damaged during shipping, handling or installation, orientation of the building, exterior shading, overhangs/fins that reduce wind speed, and areas with high daily temperature fluctuations can all increase the probability of thermal breakage. The results shown are not for any specific glazing installation and do not constitute a warranty against glass breakage.